Zoning, site plan and massing for a 50 x 100 ft double lot in the Sixplex Overlay, with a recommendation on how to underwrite it.

| Item | Value |
|---|---|
| Lot | 15.26 x 30.46 m (50 x 100 ft), 464.7 m² (5,002 sf) |
| Zone | RD (f12.0; a370; d0.4), By-law 569-2013, no exception |
| Overlays | Sixplex Overlay (600.60); height 11.0 m, 3 storeys |
| Street | 46 of 49 Lessard lots under 9 m wide; most 7.63 m and 232 m² |
| On record | City address record shows 4 existing units: check the listing |

| Setback | Required |
|---|---|
| Front yard | 6.0 m, provisional (average of 8 and 14 Lessard) |
| Rear yard | 7.615 m, 25% of the 30.46 m depth |
| Side yards | 1.2 m each |
| Length cap | 17.0 m, not binding |
| Depth limit | 19.0 m from the front yard, not binding |
| Rule | Requirement | Effect here |
|---|---|---|
| Units | 6, one building (600.60.40(1)) | Caps the yield |
| Front yard | Average of 8 and 14 Lessard, else 6.0 m (10.5.40.70(1)) | 6.0 m used |
| Rear yard | 7.615 m (10.20.40.70(2)) | Binds |
| Side yards | 1.2 m each (10.20.40.70(3)(C)) | Binds |
| Length / depth | 17.0 m / 19.0 m (10.20.40.20, .30) | Do not bind |
| Height | 11.0 m; main walls 8.5 m; 3 storeys | 3 storeys plus basement |
| FSI / coverage | Not applied to a houseplex / none mapped | No density cap |
The binding limit is the unit count, not the building. With no FSI cap, the envelope gives about 866 m² gross, which six homes split into large family units.
Front yard barely matters. City footprints show 8 and 14 Lessard at their front lot lines. A smaller front yard moves the building forward but adds at most 0.15 m of depth, because the 17 m length cap takes over.




| Option | Approval | Homes | Gross incl. basement | Gross per home | Verdict |
|---|---|---|---|---|---|
| A One sixplex | Building permit | 6 | 866 m² (9,320 sf) | 144 m² (1,550 sf) | Base case |
| B Two fourplexes | Consent plus variances | 8 | 704 m² (7,580 sf) | 88 m² (950 sf) | Upside |
| B6 Two sixplexes | Consent plus variances | 12 | 704 m² (7,580 sf) | 59 m² (630 sf) | Too tight |

The province proposes capping minimum lot sizes at 175 m². If made at that number, the 232 m² halves would no longer need lot size or frontage variances, only a consent to sever. On 2026-10-25 the ERO notice (026-0311) was still a proposal with no decision.
WatchUrban residential setbacks can be reduced to 90% unless the parcel touches a prescribed buffer (300 m of a railway, 120 m of water). Not yet checked. On the whole lot it would add a little: 13.10 x 17.00 m, about 891 m² gross.
CheckMassing study, not a survey or zoning opinion · Aerial and 3D massing: City of Toronto Open Data · Haddon Homes